Description |
Rugged wireless LAN access point and/or client for use in industrial environments. Robust metal housing for mounting on DIN rails. Hardware encrypted VPN gateway supporting up to 5 VPN tunnels.Substation EN61850, IEEE 1613 |
Port type and quantity |
RJ45 LAN combo port: 10/100/1000BASE-TX, 1000BASE-SX/LX |
Radio protocol |
IEEE802.11a/b/g/h/n WLAN interface as per IEEE802.11n, up to 450MBit/s gross bandwidth. |
Type |
BAT-REUWW9AKCI9BO799SA999H09.00.5103 |
Order No. |
BAT-REUWW9AKCI9BO799SA999H09.00.5103 |
Supported Radio Standards |
1st WLAN interface as per IEEE802.11n; 2nd WLAN interface as per IEEE802.11n |
More Interfaces
Ethernet |
RJ45 LAN combo-port: 10/100/1000BASE-TX, 1000BASE-SX/LX |
Power supply/signaling contact |
1 x terminal block, 2-pin; 1 x terminal block, 2-pin |
V.24 interface |
|
USB interface |
1 x USB to connect the AutoConfiguration Adapter ACA21-USB |
Radio technology
Antenna connector |
Reverse SMA socket, 3 x MiMo antenna connectors, 3 x MiMo antenna connectors |
Range |
Depends on type of antenna, frequency range and data rate. Use the BAT-Planner for planning your wireless network. |
Frequency band |
Supports 2.4 GHz and 5 GHz: 2400 -2483.5 MHz (ISM) and 5170 -5850 MHzSupports 2.4 GHz and 5 GHz: 2400 -2483.5 MHz (ISM) and 5170 -5850 MHz |
Modulation |
22M0F7D (DSSS/OFDM) at 2.4 GHz20M0G7D (OFDM) at 5 GHz |
Encryption |
IEEE 802.11i / WPA2 with passphrase or 802.1x and hardware-accelerated AES, closed network, WEP64, WEP128, WEP152, user authentication, 802.1x /EAP, LEPS, WPA1/TKIP. Please refer to the HiLCOS data sheet for further information. |
Power requirements
Operating voltage |
Voltage Range 1: 60/120/250 VDC (48-320 VDC) / 110/230 VAC (90-265 VAC); Voltage Range 2: 24/36/48 VDC (18-60 VDC) |
Current consumption |
17.5 W |
Ambient conditions
Operating temperature |
0 C ... 60 C |
Note |
Temperature of the surrounding air. |
Storage/transport temperature |
-40 C ... 85 C |
Relative humidity (non-condensing) |
10 % ... 95 % |
MTBF |
58 years (MIL-HDBK-217F) |
Protective paint on PCB |
No |
Mechanical construction
Dimensions (W x H x D) |
150 mm x 136 mm x 115 mm |
Mounting |
DIN Rail |
Protection class |
IP30 |
Approvals
Safety of information technology equipment |
EN 60950-1 |
Radio |
R&TTE; EN 300 328 (2.4GHz), EN 301 893 (5 GHz); EN 301 489-1, EN 301 489-17;Substation (EN61850, IEEE 1613) |
Scope of delivery and accessories
Scope of delivery |
Device, Installation user manual, CD/DVD with manual, 6 x per WLAN module 3-dBi dipole dual-band antennas, 2 × 2-pin terminal block for signal contact, 2 × 2-pin terminal block for the working voltage. |
Accessories to order separately |
External antennas; external surge protection; cables 2 m, 5 m, 15 m. Some countries does not allow all Antennas. For more information please have a look into the Hirschmann Antenna Guide; wall mount plate |