Compact linear displacement sensor with discrete output
| Supply Voltage and Current | 12 to 30V dc (10% max. ripple) @ 70 mA max. (exclusive of load) |
|---|---|
| Sensing Range | Q50AV models:50 to 150 mm Q50AN and Q50AP models:50 to 200 mm Q50BV models:100 to 300 mm Q50BN and Q40BP models:100 to 400 mm |
| Sensing Beam | Wavelength:
Q50AV and Q50BV models:685 nm typical Q50AN, Q50AP, Q50BN and Q50BP models:880 nm typical Beam Size:20 mm dia. max. |
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages |
| Output Configuration | Solid-state complementary (SPDT):NPN (current sinking) or PNP (current sourcing), depending on model |
| Output Rating | 150 mA max. each output OFF-state leakage current:less than 10 µA ON-State saturation voltage:less than 1V @ 10 mA; less than 1.5V @ 100 mA |
| Output Protection Circuitry | Protected against false pulse on power-up and continuos overload or short circuit of outputs |
| Output Response Time | Fast:4 milliseconds ON/OFF Slow:48 milliseconds ON/OFF |
| Delay at Power-up | 2 seconds |
| Sensing Repeatability | 4 millisecond response time models:1.0% of sensing distance 48 millisecond response time models:0.5% of sensing distance |
| Remote TEACH and Speed Input Impedance | 15 k ohms |
| Remote TEACH Input | To TEACH:connect gray wire to +5 to 30V dc To disable:connect gray wire to 0 to +2V dc (or open connection) |
| Adjustments | Sensing window limits:TEACH-mode programming of near and far window limits may be set using the TEACH push button or remotely using the gray TEACH wire. |
| Indicators | Range LED indicator:Green/Red
Green ON steady:target is within sensing range Red ON steady:target is outside sensing range Green flashing:outputs are overloaded OFF:sensor power OFF TEACH/Output LED indicator:Yellow/RedYellow (window limits):target is within taught window limits Yellow (fixed field):target is closer than cutoff limit Red:sensor is in TEACH mode OFF:target is outside taught window limits |
| Minimum Taught Window | Q50BVN and Q50AVP models:
Target distance @ 100 mm:1 mm window Target distance @ 150 mm:2.0 mm window Target distance @ 200 mm:3.5 mm window Target distance @ 250 mm:5.0 mm window Target distance @ 300 mm:7 mm window Q50BVN..Y and Q50BVP..Y models:Target distance @ 100 mm:2 mm window Target distance @ 150 mm:4 mm window Target distance @ 200 mm:7 mm window Target distance @ 250 mm:10 mm window Target distance @ 300 mm:14 mm window Q50BN and Q50BP models:Target distance @ 100 mm:1 mm window Target distance @ 150 mm:2.0 mm window Target distance @ 200 mm:3.5 mm window Target distance @ 250 mm:5.0 mm window Target distance @ 300 mm:7 mm window Target distance @ 350 mm:10 mm window Target distance @ 400 mm:15 mm window Q50BN..Y and Q50BP..Y models:Target distance @ 100 mm:2.0 mm window Target distance @ 150 mm:4 mm window Target distance @ 200 mm:7 mm window Target distance @ 250 mm:10 mm window Target distance @ 300 mm:14 mm window Target distance @ 350 mm:20 mm window Target distance @ 400 mm:30 mm window Q50AVN and Q50AVP models:Target distance @ 50 mm:1 mm window Target distance @ 75 mm:1.5 mm window Target distance @ 100 mm:2 mm window Target distance @ 125 mm:4 mm window Target distance @ 150 mm:5 mm window Q50AVN..Y and Q50AVP..Y models:Target distance @ 50 mm:2 mm window Target distance @ 75 mm:3 mm window Target distance @ 100 mm:4 mm window Target distance @ 125 mm:7 mm window Target distance @ 150 mm:9 mm window Q50AN and Q50AP models:Target distance @ 50 mm:1 mm window Target distance @ 75 mm:1.5 mm window Target distance @ 100 mm:2 mm window Target distance @ 125 mm:4 mm window Target distance @ 150 mm:5 mm window Target distance @ 175 mm:6 mm window Target distance @ 200 mm:7 mm window Q50AN..Y and Q50AP..Y:Target distance @ 50 mm:2 mm window Target distance @ 75 mm:3 mm window Target distance @ 100 mm:4 mm window Target distance @ 125 mm:7 mm window Target distance @ 150 mm:9 mm window Target distance @ 175 mm:12 mm window Target distance @ 200 mm:15 mm window |
| Ambient Light Immunity | less than 10,000 lux. |
| Construction | Housing:molded ABS/Polycarbonate Window lens:acrylic |
| Environmental Rating | IEC IP67; NEMA 6P |
| Connections | 5-conductor 2 m or 9 m shielded PVC-jacketed attached cable, or 5-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. |
| Operating Conditions | Temperature:-10° to +55° C Relative humidity:90% @ 50° C (non-condensing) |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave. |
| Application Note | All 15-minute warm-up for maximum performance |