Description

Lite Managed Industrial ETHERNET Rail-Switch, Ethernet/Fast-Ethernet Switch, Store and Forward Switching Mode, fanless design.

Port type and quantity

4 x 10/100BASE-TX, TP-cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity

Type

GECKO 4TX

Order No.

942 104-001

More Interfaces

Power supply/signaling contact 1 plug-in terminal block, 3-pin, no signaling contact

Network size - length of cable

Twisted pair (TP)

0 m ... 100 m

Network size - cascadibility

Line - / star topology

any

Power requirements

Operating voltage

DC 9.6 V - 32 V

Current consumption at 24 V DC

120 mA

Power consumption

2,9 W

Software

Management

Web-interface, HTTP(s) config file/firmware transfer, SNMP v1/v2/v3

Diagnostics

Device status indication (LEDs), Log-File, RMON (1) statistics, Simple interface statistics, Topology Discovery according to IEEE 802.1AB (LLDP)

Configuration

BOOTP/DHCP, DHCP Option 82, HiDiscovery

Security

SNMPv3 (authNoPriv), Possibility to disable each port

Redundancy functions

RSTP (IEEE 802.1D-2004)

Filter

TOS/DSCP prioritization (Mapping TOS/DSCP to 802.1D/p),Prioritization through 4 queues, Static unicast/multicast filter entries (up to 100)

Ambient conditions

Operating temperature

0 ºC ... 60 ºC

Storage/transport temperature

-40 ºC ... 85 ºC

Relative humidity (non-condensing)

5 % ... 95 %

MTBF

23 years

Mechanical construction

Dimensions (W x H x D)

25 mm x 114 mm x 79 mm

Mounting

DIN Rail

Weight

100 g

Protection class

IP30

Mechanical stability

IEC 60068-2-27 shock

15 g, 11 ms duration, 18 shocks

IEC 60068-2-6 vibration

3.5 mm, 5–8.4 Hz, 10 cycles, 1 octave/min; 1 g, 8.4–150 Hz, 10 cycles, 1 octave/min

EMC interference immunity

EN 61000-4-2 electrostatic discharge (ESD)

4 kV contact discharge, 8 kV air discharge

EN 61000-4-3 electromagnetic field

10 V/m (80-3000 MHz)

EN 61000-4-4 fast transients (burst)

2 kV power line, 4 kV data line

EN 61000-4-5 surge voltage

power line: 2 kV (line/earth), 1 kV (line/line), 2 kV data line IEEE1613: power line 5 kV (line/earth)

EN 61000-4-6 conducted immunity

10 V (150 kHz-80 MHz)

EMC emitted immunity

FCC CFR47 Part 15

FCC 47 CFR Part 15 Class A

EN 55022

EN 55022 Class A

Approvals

Safety of industrial control equipment

UL61010-1/-2-201

Scope of delivery and accessories

Scope of delivery

Device, terminal block, operating manual

Accessories to order separately

Rail power supply RPS 30, RPS 80 EEC or RPS 120 EEC (CC)

Product Documents
GECKO_4TX12.03.2015 - 1 MbİngilizceCheck Out