Description |
Auto-configuration adapter with extended temperature range saves the configuration data of the connected switch. It enables managed switched to be easily comissioned and quickly replaced. |
Type |
ACA11-miniDIN (EEC) |
Order No. |
943 973-001 |
More Interfaces
To the RS232 interface on the switch |
RJ11 connector |
To the RS232 interface on the PC or notebook |
n/a |
To the USB interface on the switch |
n/a |
Power requirements
Operating voltage |
via the RS232 interface on the switch |
Service
Diagnostics |
writing to ACA, reading from ACA, writing/reading not OK; |
Configuration |
via the RS232 interface of the switch and via SNMP/Web |
Ambient conditions
Operating temperature |
-40 C ... 70 C |
Storage/transport temperature |
-40 C ... 85 C |
Relative humidity (non-condensing) |
10 % ... 95 % |
MTBF |
370.9 years (MIL-HDBK-217F) |
Mechanical construction
Dimensions (W x H x D) |
90 mm x 27 mm x 12 mm |
Mounting |
plug-in module |
Weight |
35 g |
Protection class |
IP40 |
Cable length |
31.5 cm |
Mechanical stability
IEC 60068-2-27 shock |
15 g, 11 ms duration, 18 shocks |
IEC 60068-2-6 vibration |
1 g, 10 Hz - 150 Hz, 30 cycles |
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) |
6 kV contact discharge, 8 kV air discharge |
EN 61000-4-3 electromagnetic field |
10 V/m |
EMC emitted immunity
EN 55022 |
EN 55022 |
Approvals
Hazardous locations |
ISA 12.12.01 Class 1 Div. 2 (pending) |
Shipbuilding |
Germanischer Lloyd (pending) |
Safety of information technology equipment |
cUL 60950-1 (pending) |
Safety of industrial control equipment |
cUL 508 |
Employment in vehicles |
E1 |
Scope of delivery and accessories
Scope of delivery |
device, operating manual |
| ACA11-miniDIN_(EEC) | 13.04.2015 - 1 Mb | İngilizce | Check Out |