Compact, high-performance sensor in standard rectangular housing with visible red fixed-field background suppression and increased detection range opposed mode sensing.
| Supply Voltage | Fixed-Field: 10 to 30V dc (10% maximum ripple within specified limits) at less than 25 mA, exclusive of load All others: 10 to 30V dc (10% maximum ripple within specified limits) at less than 18 mA, exclusive of load |
|---|---|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages |
| Output Configuration | 100 mA with short circuit protection OFF-state leakage current:NPN: < 200 μA sinking; PNP: < 20 μA sourcing ON-state saturation voltage:NPN: < 1.6V @ 100 mA; PNP: < 3.0V @ 100 mA |
| Output Response Time | Opposed Mode: 1 millisecond ON/600 microseconds OFF Fixed-Field: 3 milliseconds ON/1.5 milliseconds OFF All others: 800 microseconds ON/OFF Note:100 millisecond delay on power-up; outputs do not conduct during this time |
| Indicators | Two LED Indicators: Power (green) and Output (yellow) Fixed-Field models: Green ON Steady: Power ON Yellow ON Steady: Black (LO) wire conducting All other models: Green ON Steady: Power ON Green flashing: Output overloaded Yellow ON steady: Black (LO) wire conducting Yellow flashing: Marginal excess gain (1 to 1.5X) Black (LO) wire conducting |
| Adjustments | Diffuse, Retroreflective, and Polarized Retroreflective models (only): Single-turn Sensitivity (Gain) adjustment potentiometer |
| Repeatability | Opposed Mode: 140 microseconds Fixed-Field: 182 microseconds All others: 155 microseconds |
| Construction | Housing: ABS Lenses: PMMA Gain Adjuster: PBT (Retro and Diffuse models only) |
| Connections | 2 m (6.5') or 9 m (30') 4-wire PVC cable, 150 mm (6 |
| Operating Conditions | Temperature: –20° to +60° C (–4° to +140° F) Relative Humidity: 95% @ 50° C (non-condensing) |
| Environmental Rating | IEC IP67 (NEMA 6) 1200 PSI washdown NEMA ICS 5 Annex F-2002 |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements method 201A (vibration: 10 to 60 Hz max., double amplitude 0.06in, maximum acceleration 10G). Also meets IEC 947-5-2; 30G 11 ms duration, half sine wave |
| Application Notes | Opposed mode sensor spacing can be reduced by alternating emitters and receivers or by applying cross talk filters (visible red models only) |
| Certifications | CE |
| Address | : | Oruçreis Mah. Tekstilkent Cd. Tekstilkent Ticaret Merkezi A8 Blok No:17/18/19 Esenler / Istanbul / Turkey |
| Telephone | : | +90 212 210 76 46 |
| Fax | : | +90 212 220 50 45 |
| : | info@dacel.com.tr |
|