CPU 1511T-1 PN:
for smaller applications with medium requirements on the program scope and processing speed, for distributed setup via PROFINET IO.
All SIMATIC S7-1500 CPUs support motion control functions. STEP 7 provides motion control instructions that are standardized in accordance with PLCopen for configuring and connecting a drive to the CPU.
Motion control with the S7-1500 supports the following technology objects:
The technology CPUs of the SIMATIC S7-1500 offer advanced motion control functions:
|
Features |
CPU 1511T-1 PN |
CPU 1515T-2 PN |
CPU 1517T-3 PN/DP |
CPU 1517TF-3 PN/DP |
|---|---|---|---|---|
|
Work memory for program, integrated |
225 KB |
750 KB |
3 MB |
3 MB |
|
Work memory for data, integrated |
1 MB |
3 MB |
8 MB |
8 MB |
|
Load memory |
Plug-in via SIMATIC Memory Card |
Plug-in via SIMATIC Memory Card |
Plug-in via SIMATIC Memory Card |
Plug-in via SIMATIC Memory Card |
|
Display diagonal |
3.45 cm |
6.1 cm |
6.1 cm |
6.1 cm |
|
Command execution times |
||||
|
0.06 µs |
0.03 µs |
0.002 µs |
0.002 µs |
|
0.072 µs |
0.036 µs |
0.003 µs |
0.003 µs |
|
0.096 µs |
0.048 µs |
0.003 µs |
0.003 µs |
|
0.384 µs |
0.192 µs |
0.012 µs |
0.012 µs |
|
Bit memories, timers, counters |
||||
|
S7 counters/timers |
2048 each |
|||
|
IEC counter |
arbitrary (only limited by the work memory) |
|||
|
IEC timer |
arbitrary (only limited by the work memory) |
|||
|
Bit memories |
16 KB |
|||
|
I/O address range |
||||
|
Inputs |
32 KB (all inputs are stored in the process image) |
|||
|
Outputs |
32 KB (all outputs are stored in the process image) |
|||
|
Motion control |
||||
|
Number of motion control resources |
800 |
2400 |
10240 |
10240 |
|
Extended functions |
Yes |
Yes |
Yes |
Yes |
|
Integral interfaces |
||||
|
PROFINET IO IRT |
1 x PN IO IRT (2 port switch) |
1 x PN IO IRT (2 port switch) |
1 x PN IO IRT (2-port switch) |
1 x PN IO IRT (2-port switch) |
|
PROFINET RT |
- |
1 x PN IO RT |
1 x PN IO RT |
1 x PN IO RT |
|
PROFINET |
- |
- |
- |
- |
|
PROFIBUS |
- |
- |
1 x DP |
1 x DP |
|
OPC UA DA server |
Yes (RT license required) |
Yes (RT license required) |
Yes (RT license required) |
Yes (RT license required) |
|
Web server |
Yes |
Yes |
Yes |
Yes |
|
Standards, approvals, certificates |
SIL according to IEC 61508: to SIL3 in each case PL according to ISO 13849: to PLe in each case |
|||
| Address | : | Oruçreis Mah. Tekstilkent Cd. Tekstilkent Ticaret Merkezi A8 Blok No:17/18/19 Esenler / Istanbul / Turkey |
| Telephone | : | +90 212 210 76 46 |
| Fax | : | +90 212 220 50 45 |
| : | info@dacel.com.tr |
|